Reflection Open Path Laser Methane Detection System for Petroleum Refinery

Product Details
Customization: Available
Brand: Hanwei Electronics
Customized: Customized
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
1998-09-11
Number of Employees
657
  • Reflection Open Path Laser Methane Detection System for Petroleum Refinery
  • Reflection Open Path Laser Methane Detection System for Petroleum Refinery
  • Reflection Open Path Laser Methane Detection System for Petroleum Refinery
  • Reflection Open Path Laser Methane Detection System for Petroleum Refinery
  • Reflection Open Path Laser Methane Detection System for Petroleum Refinery
Find Similar Products
  • Overview
  • Specification
  • Recommend Products
  • Company Profile
  • Become A Hanwei Distributor
  • FAQ
Overview

Basic Info.

Model NO.
XT-OPGD1000II
Portable
Non Portable
Certification
CE
Gas
CH4
Type
Laser Gas Analyzer
Model No
Xt-Opgd1000II
Working Voltage
DC24V±6V
Detect Principle
Laser Spectral Absorption Technology
Measuring Gas
Methane (CH4)
Measuring Range
0~100%Lelm
Accuracy
±3%Lelm
Optical Path
4m~100m
Response Time
T90≤3s
Ingress Protection
IP66 / IP67
Display Method
LCD Screen
Current Output
4-20mA (3-Wire, Permitted Error Is ±0.2mA)
Digital Output
RS485-RTU, Hart
Max. Distance
1000 Meters (Detector with Control Unit)
Transport Package
Carton
Origin
China Mainland
Production Capacity
50000 Pieces/Year

Product Description

Reflection Open Path Laser Methane Detection System for Petroleum Refinery
Reflection Open Path Laser Methane Detection System for Petroleum Refinery
XT-OPGD1000II Open Path Laser Gas Detector
XT-OPGD1000II / XT-OPGD1000II PRO open path gas detector is manufactured using high-performance photosensitive detectors and micro-controllers, combined with advanced SMD technology. It has good repeatability and temperature and humidity characteristics, as well as long service life and easy operation.
Features
High accuracy, stable performance, and long service life
3-wire 4-20mA analog signal output
3 relay outputs (low alarm, high alarm, and fault)
High performance LCD screen display, intuitive and clear
Using a magnetic rod/infrared remote control (optional) to operate the detector is easy to carry and operate
Professional matching installation brackets, easy and convenient on-site installation
Fast response, high sensitivity, only responsive to CH4, strong resistance to cross interference and water vapor
Measurement distance is maximum 100 meters
Supports Bluetooth function and can communicate data with portable instruments with Bluetooth devices
Equipped with remote upgrade function
Supports a Hart manual operator, which can perform parameter settings and query functions on the detector
Support external digital sound and light alarms
Specification
Principle
Laser spectral absorption technology
Measuring gas
Methane (CH4)
Working method
Continuous detection
Lifespan
5 years
Measuring range
0~100%LELm
Accuracy
±3%LELm
Optical path
4m~100m
Response time
T90≤3s
Security integrity
SIL 2
Explosive proof
Ex db ⅡC T6 Gb
Ex tb ⅢC T80℃ Db
Ingress protection
IP66 / IP67
Rated voltage
DC24V±6V
Max. consumption
Transmitter: 15W (no heating), 20W (heating)
Receiver: 5W (no heating), 10W (heating)
Working environment
Temp.: -40℃~70℃
Humidity: ≤95%RH (no condensation)
Pressure: 86kPa~106kPa
Storage environment
Temp.: -25℃~60℃
Humidity: 30~80%RH (no condensation)
Pressure: 86kPa~106kPa
Warm-up
After 3-minute warm-up after power on, the detector enters the normal monitoring state. Calibration can only be performed 2 hours after the detector is powered on.
Display method
LCD screen
Operation method
Magnetic rod or IR controller
(need to be selected when purchase)
Status indication
Green LED: Normal status
Yellow LED: Fault status
Red LED: Gas leakage alarm
Preset alarm value
Default value: 50%LELm
(Alarm action not locked)
Current output
4-20mA (3-wire, permitted error is ±0.2mA)
Relay output
C type, dry contact
Rated value: DC30V @3A or AC250V @3A
Digital output
RS485-RTU, HART
Enclosure
316L stainless steel
Dimension
297mmx155mmx222mm
(installation bracket included)
Fixing method
Wall-mounted or column installation
Max. optical path offset angle
±0.5°
Cable entry
NPT3/4
Weight
Transmitter: 7.2 kg, Receiver: 7.1 kg
Cable requirement
≥1.5 mm24 shielded cable, cable outer diameter should be 6mm~9mm.
Max. distance
1000 meters (detector with control unit)
Recommend Products
Reflection Open Path Laser Methane Detection System for Petroleum Refinery
Company Profile
Reflection Open Path Laser Methane Detection System for Petroleum Refinery
Become A Hanwei Distributor
Reflection Open Path Laser Methane Detection System for Petroleum Refinery
FAQ
Q1: Why do you choose our company?
A1: We are a professional manufacturer, We have seasoned engineers with over 20 years' experience in gas detection field. so we can offer products of the same quality at the best prices. 
Q2: Can I have a sample order? 
A2: The sample order to test are welcomed at the first time. 
Q3: What certification do you have? 
A3: ATEX, IECEx, CE, EN, BSI, UL, ISOD and etc. 
Q4: How do I get price information? 
A4: Sales representatives are responsible for providing detailed price information within 1 workday after get your inquiry. 
Q5: If I order a large quantity, what's the best price? 
A5: Please send the detailed enquiry to us, including item model number, quantity for each item, quality requirement, Logo and payment terms etc. We will make an accurate quotation to you at the earliest time.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now